{"product_id":"new-dent-onefile-reciproc-compatible-rotary-file","title":"New Dent Onefile Reciproc Compatible Rotary File","description":"\u003cdiv class=\"dr-product-desc\"\u003e\n\u003cstyle\u003e\n  .dr-product-desc{font-size:15px;line-height:1.7;color:#3a3a3a;max-width:100%;word-wrap:break-word}\n  .dr-product-desc .section-title{font-size:1.1em;font-weight:700;margin:1.75em 0 .65em;padding:8px 12px 8px 14px;border-left:4px solid #0077c8;color:#1a1a1a;line-height:1.35;background:#eef6fb}\n  .dr-product-desc .section-title:first-of-type{margin-top:0}\n  .dr-product-desc p{margin:0 0 .9em;line-height:1.7}\n  .dr-product-desc ul{margin:.25em 0 1em;padding-left:1.3em}\n  .dr-product-desc li{margin-bottom:.45em;line-height:1.65}\n  .dr-product-desc strong{font-weight:600;color:#222}\n  .dr-product-desc .key-highlight{background:linear-gradient(135deg,#f0f7ff 0%,#e8f4fc 100%);border:1px solid #b8d9f0;border-left:5px solid #0077c8;border-radius:10px;padding:20px 22px 18px;margin:1.75em 0;box-shadow:0 2px 12px rgba(0,119,200,.08)}\n  .dr-product-desc .key-highlight::before{content:\"What sets this product apart\";display:inline-block;font-size:.72em;font-weight:700;letter-spacing:.04em;text-transform:uppercase;color:#fff;background:#0077c8;padding:5px 12px;border-radius:4px;margin-bottom:12px}\n\u003c\/style\u003e\n\u003cp class=\"section-title\"\u003e\u003cstrong\u003eOnefile NiTi canal file — Reciproc alternative (6-pack)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVDW Reciproc alternative NiTi canal file in a 6-piece pack. One NiTi single-file system: usable in reciprocating or non-reciprocating systems regardless of whether your endo motor runs in reciprocation or full rotation (360°), aiming to finish canal treatment with a single file — at about half the price of similar products.\u003c\/p\u003e\n\u003cdiv class=\"key-highlight\"\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e On conventional endodontic motors with full rotation, because of the cutting side of the blades these files must be run counter-clockwise (R); blades and files do not work in the normal clockwise direction. The motor must be able to run in reverse. Reciprocating devices need no modification.\u003c\/p\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eNanotechnology coating for longer life (more uses) and higher resistance to fracture and wear.\u003c\/li\u003e\n\u003cli\u003eConvex triangular cross-section for effective cutting and NoScrew effect in the canal.\u003c\/li\u003e\n\u003cli\u003eCurrent short-term promotional pricing offers about half the price of similar products.\u003c\/li\u003e\n\u003cli\u003eThe system aims to finish treatment with a single rotary file; successful in some cases, but attention points and modifications\/pre-files may be needed in complicated canals.\u003c\/li\u003e\n\u003cli\u003eFiles come in 3 types for narrow, medium and wide canals.\u003c\/li\u003e\n\u003cli\u003eUsed at 250–450 RPM with 2.5 Ncm torque.\u003c\/li\u003e\n\u003cli\u003eTip sizes: narrow #20, medium #25, wide #40 (specify when ordering).\u003c\/li\u003e\n\u003cli\u003e1 box = 6 pieces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"section-title\"\u003e\u003cstrong\u003eTaper and obturation notes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the company catalogue states a taper angle of 0.08°, tests with tapered gutta-percha during filling showed an incline around 0.06. Canals prepared with these files are filled with 0.06 gutta for sizes 20 and 25 (20\/06) (25\/06). For size 40, use Protaper F4 gutta or 40\/04 gutta (40\/06 gutta falls 1–2 mm short); with the second option (40\/04), lateral condensation with at least one more gutta is recommended. System gutta and tapered paper points are available in the EndoMarket section of the site.\u003c\/p\u003e\n\u003cp class=\"section-title\"\u003e\u003cstrong\u003eClinical use rules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs with all rotary systems, with the single-file system determine working length before treatment, pre-flare with size 10–15 files and open the trajectory. Especially important: single-file systems remove more debris at once than other systems, so after 3–4 strokes recapitululate and irrigate the canal, clean the instrument, then continue without forcing. Insisting on going directly to working length in one pass increases file fracture risk.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"New Dent","offers":[{"title":"No. 20","offer_id":46033696260140,"sku":"DRM.2160-20","price":50.0,"currency_code":"USD","in_stock":true},{"title":"No. 25","offer_id":46033696292908,"sku":"DRM.2160-25","price":50.0,"currency_code":"USD","in_stock":true},{"title":"No. 40","offer_id":46033696325676,"sku":"DRM.2160-40","price":50.0,"currency_code":"USD","in_stock":true},{"title":"Assortment","offer_id":46033696358444,"sku":"DRM.2160-A","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2699\/7450\/files\/555.png?v=1787581064","url":"https:\/\/www.dentrealstore.com\/en-de\/products\/new-dent-onefile-reciproc-compatible-rotary-file","provider":"DentrealStore","version":"1.0","type":"link"}